Sign in or 

| Version | User | Scope of changes |
|---|---|---|
| Sep 1 2010, 10:39 AM EDT | gmack | 3 words added, 6 words deleted |
| Jul 24 2010, 8:04 AM EDT | gmack | 8 words deleted |
| Adult | Other related pages of interest |
| Name of projection | Finger - Oblique |
| Area Covered | Entire digit of interest and distal half of adjoining metacarpal |
| Pathology shown | fractue dislocation |
| Radiographic Anatomy | Hand Radiographic Anatomy |
| IR Size & Orientation | 18 x 24cm Landscape, divided for multiple finger images, use lead masking |
| Film / Screen Combination | Detail (CR and DR as recommended by manufacturer) |
| Bucky / Grid | No |
| Filter | No |
| Exposure | 48kVp 4mAs |
| FFD / SID | 115cm |
| Central Ray | Directed to the proximal interphalangeal joint of affected digit Perpendicular to the IR |
| Collimation | Centre: Proximal interphalangeal joint Shutter A: To include distal phalanx to half the adjoining metacarpal Shutter B: To include soft tissue |
| Markers | Distal/Lateral Marker orientation AP |
| Shielding | Gonadal (check your department's policyn/a guidelines) |
| Respiration | Not applicable |
| Positioning |
|
| Critique | Positioning
|
| Special Notes |