This page contains radiographic exposure values

Adult Scapula

Region View kVp mAs Cassette Grid Distance
ScapulaAP6516RegularYes100 - 115cm (40 inches)

Lateral (Y)7020RegularYes100 - 115cm (40 inches)

Oblique7025RegularYes100 - 115cm (40 inches)

Paediatric Scapula

Region View kVp mAs Cassette Grid Distance
ScapulaAP6012RegularYes100 - 115cm (40 inches)

Lateral (Y)6516RegularYes100 - 115cm (40 inches)

Oblique6520RegularYes100 - 115cm (40 inches)


These are average exposures using a KodakCarestream CR system, exposures may vary dramatically between different film/screen combinations andcombinations, CR /or DR systems