Abdominal Artifacts and DevicesThis is a featured page

Introduction
It is not unusual to see artifacts and surgical devices on abdminal plain film images. An unidentified appearance of an artifact or implanted device can be confusing and may, in some patients, result in further unneccesary imaging. This page provides examples of artifacts and devices commonly demonstrated on abdominal plain film imaging.

Stoma Bag Ring and Staples
Stoma and suturesThis patient has had abdominal surgery. There are multiple metallic sutures (white arrow) and a stoma artifact (black arrow).

Gall stones noted (not arrowed)

Stoma
This is commonly referred to as a colostomy bag. It can present an artifact from the colostomy bag itself and/or from the contents of the bag.
stoma bag
http://www.rothhomehealth.com/resource/products/Images/11152-1.jpg
The ring appearance seen on abdominal plain film associated with patients wih a colostomy bag is a shadow of the hard plastic ring (arrowed) which the stoma bag attaches to.


skin staples
http://beatingmycancer.org/images/staples.jpg
Metal staples are commonly used fur skin suturing of the anterior abdominal wall.

IVC Filter
IVC filterThe arrowed structure is an inferior vena cava (IVC) filter (? Günther Tulip filter, Cook Medical). IVC filters are most commonly used to prevent pulmonary embolism in patients with deep vein thrombosis. The IVC filter is designed to catch large thrombus preventing it from progressing to the pulmonary arteries

IVC filter
http://upload.wikimedia.org/wikipedia/en/b/ba/Mar07_090.jpg



Aortic Endovascular Stent
Aortic Endovascular stentThis patient has an aortic endovascular stent (arrowed). These stents are commonly employed to treat abdmininal aortic aneurysm (EVAR - endovascular aneurysm repair).




Also noted
  • pelvic phleboliths
  • costal cartilidge calcification
  • basal lung disease
  • skin folds overlying lateral aspect of liver
endovascular stent
adapted from http://www.aorticstents.com/
This is an endovascular stent with 'trouser legs'. The two legs are deployed into the lumens of the common iliac arteries.


Biliary and Renal Stent
Biliary and Renal StentThis is a DR erect abdominal plain film. The image demonstrates the following

  • biliary stent x 2 (white arrows)
  • Renal stent (black arrow)
  • metallic sutures (grey arrow)

Note patient probably has small bowel obstruction
Biliary Stent
biliary wire stent
source: http://www.tradekorea.com/products/Stent.html
One of the biliary stents is a wire stent. This stent has been deployed within the bile duct.
biliary stent
Source: http://www.cookmedical.com/esc/dataSheet.do?id=1240
This is a biliary stent which is also used to drain obstructed biliary ducts.
Ureteric Stent
Source: http://www.bioteque.com/images/products/ul/pigtailuretheralstent-nostring.jpg
This is one end of a ureteric stent that is commonly refered to as a double J stent.



M.J.Fuller
M.J.Fuller
Latest page update: made by M.J.Fuller , Feb 18 2010, 6:58 AM EST (about this update About This Update M.J.Fuller Edited by M.J.Fuller